HomeAboutUsApplicationsServiceContact

 

Our laser products are used for a wide variety of applications. We put them into two major categories:

1. Power featured
These lasers can be used for a variety of applications such as: material processing, cutting, welding, drilling, marking, coding, surgery, skin resurfacing, wound healing, etc. If your are interested in this area, click here (Laser Table I). For applications requiring high level of power and wavelength stability, click here (Laser Table II).

2. Wavelength featured
These are our grating tuned lasers, which can be used for: spectroscopy, trace gas analysis, breath analysis, environmental monitoring, industrial process control, medical diagnostics, night vision illumination, infrared interferometry, remote sensing, free space optical communications, laser radar, etc. If you are interested in this area, click here (Laser Table III)

For a list of available additonal options please click here.

TABLE I.  Standard Lasers: Also featuring Super Pulse (P) capabilities, and used in a wide array of applications from Industrial Material Processing, Marking, Medical Applications, etc.

Model

L3

L4

L5 / P

L12 / P

L15 / P

L25 / P

AL30 / P L50 / P

CW / Average

400mW

1W

5W / 4W

12W / 7W

15W / 7W

25W / 14W

35W / 15W 50W / 25W

Peak Power (P)

-

-

20W

30W

30W

60W

70W 100W

M2

< 1.1

< 1.1

< 1.1

< 1.1

< 1.1

< 1.1

< 1.2 < 1.2

Beam Waist Dia.

2.4 mm

2.4 mm

2.4 mm

2.4 mm

2.4 mm

2.4 mm

2.4 mm 2.4 mm

Waist Location

Output coupler

Output coupler

Output coupler

Output coupler

Output coupler

Output coupler

Output coupler Output coupler

Full Div. Angle

5.5 mrad

5.5 mrad

5.5 mrad

5.5 mrad

5.5 mrad

5.5 mrad

5.5 mrad 5.5 mrad

Power Stability

±20%

±15%

±10%

±10%

±10%

±5%

±5% ±5%

Wavelength (µm)

10.3 - 10.8

10.3 - 10.8

~10.6

~10.6

~10.6

~10.6

~10.6 ~10.6

Rise Time (µs)

200

200

200 / 100

200 / 100

200 / 100

200 / 100

200 / 100 200 / 100

Fall Time (µs)

200

200

200 / 100

200 / 100

200 / 100

200 / 100

200 / 100 200 / 100

Voltage (DC)

12

12

28 / 48

28 / 48

36 / 48

28 / 48

36 / 48 28 / 48

Current (amps)

2

4

5 / 4

6 / 5

7 / 5

13 / 9

16 / 12 28 / 18

Cooling Method

Forced Air

Forced Air

Forced Air

Forced Air

Forced Air

Forced Air

Forced Air Forced Air

Working Temp

5-40 C

5-40 C

5-40 C

5-40 C

5-40 C

5-40 C

5-40 C 5-40 C
 

     

TABLE II.  Stabilized, Gratingless Tuned: Power and Wavelength Stabilized Lasers, used for Test instrumentation, Interferometry, Accurate Thermal Source, etc.  

Model

L3S

L4S

L20S

MeritS

CW power

400mW

1W

25W

50W

M2

< 1.1

< 1.1

< 1.1

< 1.2

Beam Waist Dia.

2.4 mm

2.4 mm

2.4 mm

2.4 mm

Waist Location

Output coupler

Output coupler

Output coupler

Output coupler

Full Div. Angle

5.5 mrad

5.5 mrad

5.5 mrad

5.5 mrad

Power Stability

±2%

±2%

±2%

±5%

Wavelength (µm)

10.3-10.8

10.3-10.8

10.5 - 10.63

10.5 - 10.7

Rise Time (µs)

200

200

200

200

Fall Time (µs)

200

200

200

200

Voltage (DC)

12

12

2 8

2 8

Current (amps)

4

4

13

28

Cooling Method

Forced Air / Water 0.5 GPM

Forced Air / Water 0.5 GPM

Water 0.5 GPM

Forced Air / Water 0.5 GPM

Working Temp

5-40 C

5-40 C

5-40 C

5-40 C
 


TABLE III.  Grating Tuned Lasers: Wavelength Tunable Lasers and Super Pulsed (P), used for Spectroscopy, Trace Gas Analysis, Sensing, Medical Diagnostics, Environment Monitoring, etc.

Model

L4G

MeritG / P

L20G / P

L50G / P

CW / Average

200mW

2W / -

8W / 5W

18W / 8W

Peak Power (P)

-

6W

24W

40W

M2

< 1.2

< 1.2

< 1.2

< 1.2

Beam waist dia.

2.4 mm

2.4 mm

2.4 mm

2.4 mm

Waist location

Output coupler

Output coupler

Output coupler

Beam exit

Full Div. Angle

5.5 mrad

5.5 mrad

5.5 mrad

5.5 mrad

Power stability

±10%

±5%

±5%

±5%

Wavelgth (µm)

9.3 - 10.8

9.2 - 10.8

9.2 - 10.7

9.2 - 10.7

No. of Lines

35

50 / 55

50 / 55

60 / 65

Rise time (µs)

200

200 / 100

200 / 100

200 / 100

Fall time (µs)  

200

200 / 100

200 / 100

200 / 100

Voltage (DC)

12

28 / 48

28 / 48

28 / 48

Current (amps)

4

8 / 5

14 / 9

28 / 18

Cooling Req

Forced Air / Water 0.5 GPM

Forced Air / Water 0.5 GPM

Water 0.5 GPM

Water 0.5 GPM

Working Temp

5-40 C

5-40 C

5-40 C

5-40 C

 

TABLE IV. CO Lasers: Our line of CO lasers featuring lower wavelength ranges

Model

L20GCO

L20CO

L50CO

CW power

400mW

3W

6W

M2

< 1.2

< 1.4

< 1.3

Beam Waist Dia.

2.2 mm

2.2 mm

2.2 mm

Waist Location

Output coupler

Output coupler

Beam Exit

Full Div. Angle

5.5 mrad

5.5 mrad

5.5 mrad

Power Stability

±10%

±5%

±5%

Wavelgth (µm)

5.3 - 5.7

5.2 - 5.6

5.2 - 5.8

Rise time (µs)

500

500

500

Fall time (µs)

500

500

500

Voltage (DC)

28

28

28

Current (amps)

14

14

28

Cooling Method

Water 0.5GPM

Water 0.5GPM

Water 0.5GPM

Working Temp

5-40 C

5-40 C

5-40 C

 

Home  ||  About Us  ||  Products  ||  Applications  ||  Service  ||  Contact