Our laser products are used for a wide variety of applications. We put
them into two major categories:
1. Power featured
These lasers can be used for a variety of applications such as: material processing, cutting, welding, drilling, marking, coding, surgery, skin
resurfacing, wound healing, etc. If your are interested in this area, click here
(Laser Table I). For applications requiring high level of
power and wavelength stability, click here (Laser Table II).
2. Wavelength featured
These are our grating tuned lasers, which can be used for: spectroscopy, trace gas analysis, breath analysis, environmental monitoring, industrial
process control, medical diagnostics, night vision illumination, infrared interferometry,
remote sensing, free space optical communications, laser radar, etc. If you are
interested in this area, click here (Laser Table III)
For a list of available additonal options please click here.
TABLE I.
Standard Lasers: Also featuring Super Pulse (P) capabilities, and used in a wide array of applications from Industrial Material Processing, Marking, Medical Applications, etc.
| Model |
L3 |
L4 |
L5 / P |
L12 / P |
L15 / P
|
L25 / P |
AL30 / P |
L50 / P |
| CW
/ Average
|
400mW |
1W |
5W / 4W |
12W / 7W |
15W / 7W |
25W / 14W |
35W / 15W |
50W / 25W |
| Peak Power (P) |
- |
- |
20W |
30W |
30W |
60W |
70W |
100W |
| M2 |
< 1.1
|
< 1.1 |
< 1.1 |
< 1.1 |
< 1.1 |
< 1.1 |
< 1.2
|
< 1.2
|
| Beam Waist Dia.
|
2.4 mm |
2.4 mm |
2.4 mm |
2.4 mm |
2.4 mm |
2.4 mm |
2.4 mm
|
2.4 mm
|
| Waist Location
|
Output coupler |
Output coupler |
Output coupler |
Output coupler |
Output coupler |
Output coupler |
Output coupler
|
Output coupler
|
| Full Div. Angle |
5.5 mrad |
5.5 mrad |
5.5 mrad |
5.5 mrad |
5.5 mrad |
5.5 mrad |
5.5 mrad
|
5.5 mrad
|
| Power Stability
|
±20% |
±15%
|
±10% |
±10% |
±10% |
±5%
|
±5%
|
±5%
|
| Wavelength (µm)
|
10.3 - 10.8 |
10.3 - 10.8 |
~10.6 |
~10.6 |
~10.6 |
~10.6 |
~10.6 |
~10.6 |
| Rise Time (µs)
|
200 |
200 |
200 / 100
|
200 / 100
|
200 / 100
|
200 / 100
|
200 / 100
|
200 / 100
|
| Fall Time (µs)
|
200 |
200 |
200 / 100
|
200 / 100
|
200 / 100
|
200 / 100
|
200 / 100
|
200 / 100
|
|
Voltage (DC) |
12 |
12 |
28 / 48 |
28 / 48 |
36 / 48 |
28 / 48 |
36 / 48 |
28 / 48 |
|
Current (amps) |
2 |
4 |
5 / 4 |
6 / 5 |
7 / 5 |
13 / 9 |
16 / 12 |
28 / 18 |
|
Cooling Method |
Forced Air |
Forced Air |
Forced Air |
Forced Air |
Forced Air |
Forced Air |
Forced Air |
Forced Air |
| Working Temp
|
5-40 C |
5-40 C |
5-40 C |
5-40 C |
5-40 C |
5-40 C |
5-40 C |
5-40 C |
TABLE
II. Stabilized, Gratingless Tuned: Power and Wavelength Stabilized Lasers, used for Test
instrumentation, Interferometry, Accurate Thermal Source, etc.
| Model |
L3S
|
L4S
|
L20S
|
MeritS |
| CW
power |
400mW |
1W |
25W |
50W |
| M2 |
< 1.1 |
< 1.1 |
< 1.1 |
< 1.2
|
| Beam Waist Dia. |
2.4 mm |
2.4 mm |
2.4 mm |
2.4 mm
|
| Waist Location |
Output coupler |
Output coupler |
Output coupler |
Output coupler
|
| Full
Div. Angle |
5.5 mrad |
5.5 mrad |
5.5 mrad |
5.5 mrad
|
| Power Stability
|
±2%
|
±2%
|
±2%
|
±5%
|
| Wavelength (µm)
|
10.3-10.8
|
10.3-10.8
|
10.5 - 10.63 |
10.5 - 10.7 |
Rise
Time (µs)
|
200 |
200 |
200 |
200
|
| Fall
Time (µs)
|
200 |
200 |
200 |
200
|
|
Voltage (DC) |
12
|
12
|
2
8
|
2
8
|
| Current (amps)
|
4 |
4 |
13 |
28 |
| Cooling Method |
Forced Air / Water 0.5 GPM
|
Forced Air / Water 0.5 GPM
|
Water 0.5 GPM |
Forced Air / Water 0.5 GPM
|
| Working
Temp
|
5-40 C |
5-40 C |
5-40 C |
5-40 C |
TABLE
III. Grating Tuned Lasers: Wavelength Tunable Lasers and Super Pulsed (P), used for Spectroscopy, Trace Gas Analysis, Sensing, Medical Diagnostics, Environment
Monitoring, etc.
| Model |
L4G
|
MeritG / P
|
L20G / P |
L50G / P
|
| CW
/ Average
|
200mW |
2W / - |
8W / 5W |
18W / 8W |
| Peak Power (P) |
- |
6W |
24W |
40W |
| M2
|
< 1.2
|
< 1.2
|
< 1.2
|
< 1.2
|
| Beam
waist dia.
|
2.4 mm
|
2.4 mm
|
2.4 mm
|
2.4 mm
|
| Waist
location
|
Output coupler
|
Output coupler |
Output coupler |
Beam exit |
| Full
Div. Angle
|
5.5 mrad
|
5.5 mrad
|
5.5 mrad
|
5.5 mrad
|
| Power stability
|
±10%
|
±5%
|
±5%
|
±5%
|
| Wavelgth (µm)
|
9.3 - 10.8
|
9.2 - 10.8 |
9.2 - 10.7 |
9.2 - 10.7 |
| No. of Lines
|
35 |
50 / 55 |
50 / 55 |
60 / 65 |
| Rise
time (µs)
|
200 |
200 / 100
|
200 / 100
|
200 / 100
|
| Fall
time (µs)
|
200
|
200 / 100
|
200 / 100
|
200 / 100
|
| Voltage (DC) |
12
|
28 / 48
|
28 / 48
|
28 / 48
|
| Current (amps) |
4 |
8 / 5 |
14 / 9 |
28 / 18 |
| Cooling
Req |
Forced Air / Water 0.5 GPM |
Forced Air / Water 0.5 GPM |
Water 0.5 GPM |
Water 0.5 GPM |
| Working
Temp |
5-40 C |
5-40 C |
5-40 C |
5-40 C |
TABLE
IV. CO Lasers: Our line of CO lasers featuring lower wavelength ranges
Model
|
L20GCO
|
L20CO |
L50CO |
CW
power
|
400mW |
3W
|
6W |
M2
|
< 1.2
|
< 1.4
|
< 1.3
|
Beam
Waist Dia.
|
2.2 mm
|
2.2 mm
|
2.2 mm
|
Waist
Location
|
Output coupler
|
Output coupler
|
Beam Exit |
Full
Div. Angle
|
5.5 mrad
|
5.5 mrad
|
5.5 mrad
|
Power Stability
|
±10%
|
±5%
|
±5%
|
Wavelgth (µm)
|
5.3 - 5.7 |
5.2 - 5.6 |
5.2 - 5.8 |
Rise
time (µs)
|
500 |
500 |
500 |
Fall
time (µs)
|
500 |
500 |
500 |
Voltage (DC) |
28 |
28 |
28 |
Current (amps) |
14 |
14 |
28 |
Cooling Method |
Water 0.5GPM |
Water 0.5GPM |
Water 0.5GPM |
Working Temp |
5-40 C |
5-40 C |
5-40 C |
|